A justified question: for half a century, AAS users had to put up with abstract numerical values.
How they come about and whether they are actually accurate remains a secret. The High-Resolution Continuum Source (HR-CS) AAS used in the contrAA® series from Analytik Jena provides the AAS user with significantly more information. Thanks to the combination of a xenon lamp covering the entire relevant wavelength range, a high-resolution spectrometer and a CCD-detector, it has become possible to visually represent the absorption spectra of samples...
Spectris plc, the productivity-enhancing instrumentation and controls company, today announces that it has acquired the business and assets of the Canadian company La Corporation Scientifique Claisse Inc. (‘Claisse’), a global market leader in sample preparation for atomic spectroscopy (including X-ray) analysis, for an undisclosed sum.
Revenues for the year ending March 2014 were CAD 13 million. Claisse designs, manufactures and sells consumables and instruments used to prepare consistent and comparable samples for spectroscopic analysis in mining, pharmaceutical, academic research and industrial applications. Claisse will become part of the Materials Analysis segment and will be integrated into PANalytical, combining two leaders in fusion and X-ray fluorescence (XRF) analysis...
Thermo Fisher Scientific has developed a high-performance liquid chromatography method to determine 20 polycyclic aromatic hydrocarbons (PAHs) in environmental waters using on-line solid-phase extraction (SPE) for sample preparation.
This approach moves the off-line sample preparation procedures of U.S. Environmental Protection Agency (EPA) Methods 550 and 550.1 on line to save time and labor. Application Note (AN) 1085: Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water demonstrates reduced method detection limits for ultraviolet and fluorescence detections, thus enabling a convenient method for determination of PAHs in environmental and drinking water...
Read MoreWorld premiere: nano-Raman (TERS) Mapping Live on an Exhibition Booth!Jul 1, 2014
Nano-Raman performed with tip-enhanced Raman spectroscopy (TERS), and especially nano-Raman imaging, still has the reputation of being a difficult measurement.
Last week, to demonstrate that this can now be performed under regular conditions, the HORIBA team has set up a “XploRA nano” system on a standard optical table running without air damping. TERS imaging was perform without any trouble even when visitors were stopping by to discuss the technique with the team. “Thanks to our unique integrated solution with AIST-NT (Novato, CA, USA), using tuning fork TERS probes manufactured by HORIBA and...
Analytik, leading suppliers of innovative analytical instrumentation, report on how the LabSpec Vis-NIR portable spectrometer from PANalytical Boulder (formerly ASD Inc) is being used to study historic materials.
Analytik have supplied LabSpec Vis-NIR spectrometers in the world of heritage research where non-destructive identification of materials is vital both in terms of preservation and restoration. Systems are in use in museums, galleries, libraries and historic properties where applications include the dating of historic parchments and the analysis of pigments on manuscripts. Dr Craig Kennedy is a senior lecturer in the School of the...
When it comes to pursuing breakthroughs in proteomics research, there’s no such thing as too much scanning speed, as long as data quality remains high.
Addressing this demand is the latest addition to the best-selling Q Exactive family of Thermo Scientific liquid chromatography-mass spectrometry (LC-MS) systems, the Thermo Scientific Q Exactive HF instrument. The Thermo Scientific Q Exactive HF system is making its debut at the 62nd ASMS Conference on Mass Spectrometry and Allied Topics, booth 127, and at the Holiday suite in the Hilton Baltimore Hotel...
As protein-based drugs become more important in treating major diseases, producers face the critical challenge of deeply characterizing these highly-complex molecules for efficacy and safety, as well as to meet quality requirements.
Now there’s a new software tool designed to increase the speed, quality and confidence in comprehensive biotherapeutic protein characterization useful for drug development and production quality control. Thermo Scientific PepFinder software is making its debut at the 62nd ASMS Conference on Mass Spectrometry and Allied Topics, booth 127, and at the company’s hospitality suite: Holiday, Baltimore Hilton. PepFinder software is designed to...
The UK’s University of Leeds Electron Microscopy and Spectrocopy Centre (LEMAS), internationally renowned as a leading research centre in microscopic and spectroscopic characterisation, has extended its electron microscopy capability by installing the first of a new generation of high performance cold field emission SEMs.
The Hitachi SU8230 at Leeds is the first SEM in Europe to utilise the latest high stability CFE technology and will be used for nanomaterial characterisation in pharmaceutical, catalysis and energy applications. Ultra-low voltage capabilities, including low-loss BSE imaging, will provide information on the true-surface and electrical properties of materials at nanoscale resolution. Being equipped with angle-selective BF and DF STEM, the SU8230 will enable correlative studies with TEM, especially on...
A new brochure from Malvern Instruments details the range of detectors available for Gel Permeation/Size Exclusion Chromatography (GPC/SEC).
It also provides scientists with the background required to choose the detector array most appropriate to maximizing information flow and experimental productivity. Available as standalone units, or as part of a fully integrated Viscotek multi-detection GPC/SEC system, Malvern’s GPC/SEC detectors provide highly accurate analysis of polymer and protein macromolecular features, such as molecular weight, and combine to offer advanced insight into molecular structure...
Laboratories analyzing food, the environment, and biological samples for compounds like dioxins, PCBs, pesticides, steroids and other challenging analytes now have access to a new generation of GC-MS/MS from Thermo Fisher Scientific, designed to deliver more sensitivity at faster speeds than its predecessor.
The new Thermo Scientific TSQ 8000 Evo triple quadrupole GC-MS is making its debut at the 62nd ASMS Conference on Mass Spectrometry and Allied Topics at the company’s hospitality suite: Holiday, Baltimore Hilton. The TSQ 8000 Evo system improves on the features of its predecessor, the TSQ 8000, with new EvoCell technology, demonstrated in company-run experiments to triple selected reaction monitoring (SRM) transition rates without compromising sensitivity...
Novel Program Increases Lab Accuracy and Unknown Compound Identification with Single Quadrupole Instrumentation
Cerno Bioscience and Agilent Technologies, Inc. (NYSE: A) today announced Agilent will distribute Cerno Bioscience’s MassWorks™ calibration and analysis software with all Agilent GC/MSD systems. This novel calibration technology increases the mass accuracy of Agilent's single quadrupole GC/MSD to enable unknown compound identification. This process normally requires more complex instruments such as Time-of-Flight (TOF) mass spectrometers "Making Cerno MassWorks directly available to GC/MSD users through Agilent channels opens the qualitative power of accurate mass information to...
Laboratories analyzing environmental, clinical research/toxicological, and food samples have a powerful new data tool expected to save time and money while identifying compounds with high levels of confidence.
Thermo Fisher Scientific announces its high resolution accurate mass (HRAM) spectral library at the 62nd ASMS Conference on Mass Spectrometry and Allied Topics. “This is a true library with full, high-resolution spectra for every compound it contains,” said Jennifer Massi, program manager, environmental and food safety for Thermo Fisher Scientific. “In fact, we ran multiple MS/MS spectra for each compound, and each was analyzed at multiple collision energies. This is designed to enhance method flexibility and confidence in results.”...
Waters Introduces Xevo G2-XS QTof and Xevo TQ-S micro Mass Spectrometers, Taking Benchtop Quantitative and Qualitative MS Applications to New Levels
Company also Expands ionKey/MS System to SYNAPT and Xevo Time-of-Flight Mass Spectrometers with New UPLC-Grade iKey Chemistries. Waters Corporation (NYSE:WAT) today introduced two new Xevo® mass spectrometers and expanded the ionKey/MS System at the 62nd conference of the American Society of Mass Spectrometry (ASMS). The Waters® Xevo G2-XS mass spectrometer, a new high performance benchtop quadrupole time-of-flight (QTofTM) mass spectrometer, and the Xevo TQ-S micro, a new and compact benchtop tandem quadrupole mass spectrometer, take...
J.G. Finneran's Ultra Low Bleed Aluminum Seals and 9mm R.A.M.™ Caps are lined using LCMS high purity septa.
The ultra low bleed septa are ideal for very sensitive applications such as Mass Spec or when multiple injections are required. Our Ultra Low Bleed Septa eliminates particulates with no interfering peaks. Aluminum seals are available in 11mm and 20mm crimp finish. The 9mm R.A.M.™ short thread closures with a smooth or ribbed finish, are available with either a friction fit or bonded ultra low bleed PTFE/Silicone Septa....
Its space saving stackable design allows you to make the most of your lab space and the modular design allows for different combinations to suit single and multiple GC applications.
Looking to the future, the F-DGSi Modular Alliance Series can also accommodate Helium to Hydrogen conversion as natural resources run low and costs rise, with our high purity H2 generator model WM-H2. Hydrogen provides many advantages over helium including, higher resolution, shorter run times, longer column life, and cost savings. Many instrument manufacturers now provide resources to make switching carrier gas easier....
13mm and 25mm Syringe Filters, from J.G. Finneran Associates, are manufactured using polypropylene medical-grade housings with Luer-Lock and Luer-Slip fittings in compliance with ISO 594-1.
Each filter is sealed, using an external ring insert, to maintain the membrane integrity and best performance. Filters are color-coded for easy identification of the filter’s membrane type. The Certified Filters are supplied with a Certificate of Quality, batch-to-batch, to guarantee product performance and quality. The filters are visually inspected following quality specifications. Each batch of filters is tested for external dimensions, bubble point, filter integrity, water flow rate, UV extractable, and compliance with all technical procedures, manufacturing specifications, and quality controls for release. Tests are performed by an independent laboratory....
J.G. Finneran Associates is a highly recognized, respected and independent, family-owned and operated glass and plastic manufacturer.
A specialist in chromatography, biotechnology and environmental products which include glass and plastic vials, closures and accessories, the patented 96-Well Multi-Tier™ Micro Plate System and accessories, VOA/EPA vials, and sampling bottles and jars – pre-cleaned and pre-cleaned/certified. Their manufacturing operations located in Vineland, NJ, USA, combine the most modern and highly automated equipment with our own custom designed machinery to handle volume production while maintaining product integrity and the highest quality products in the industry.
ACE SuperC18 and SuperPhenylHexyl UHPLC/HPLC columns offer excellent stability across an extended pH range, allowing chromatographers to routinely exploit beneficial selectivity changes at low, intermediate and high pH.
These columns are designed for use with LC/MS compatible buffers and offer ultra-low bleed for improved LC/MS compatibility. They can be used with MeOH and MeCN mobile phases and offer rapid column equilibration without memory effects. ACE SuperC18 columns offer excellent stability up to pH 11.0/11.5 and ACE SuperPhenylHexyl columns offer excellent stability up to pH 11.0.
Anasys Instruments reports on EPFL’s latest research on lysozyme droplets and α-synuclein macromolecular aggregates illustrating application of the nanoscale AFM-IR technique to demonstrate α to β secondary structure transition associated with amyloid formation.
Proteins aggregating into amyloid structures are involved in important neurodegenerative disorders such as Alzheimer’s and Parkinson’s disease. During aggregation, initially monomeric proteins undergo internal structural rearrangement forming amyloid fibrils with a universal cross β -sheet quaternary structure. During fibrillation, several coexisting amyloidogenic species are formed and the study of these species would allow...
PANalytical presented their Epsilon 3X automation option to the public at the Finnish Mining Seminar (4-6 June, Oulu, Finland).
With the launch of the innovative (patent-pending) Epsilon 3X automation, PANalytical combines the advantages of a benchtop X-ray fluorescence (XRF) spectrometer with an automation environment. The Epsilon 3X automation option is a simple and flexible solution interfacing your existing Epsilon 3 or new Epsilon 3X analyzer to any sample preparation equipment. The instrument is enclosed in a sealed cabinet for safe operation and...
Markes International, a world leader in instrumentation for trace organic analysis, has announced the launch of a Humidifier Accessory, which extends the capability of their Micro-Chamber/Thermal Extractor™ by supplying it with humidified air or gas.
Markes’ Micro-Chamber/Thermal Extractor has gained popularity over recent years as a versatile tool for rapidly sampling volatile organic vapours released from everyday products such as toys, car trim and construction materials, or odour profiles from foods and cosmetics. Now the capability of the Micro-Chamber/Thermal Extractor has been further extended by the release of the Humidifier Accessory, which...
Thermo Fisher Scientific has developed a new ion chromatography (IC)-based method that overcomes typical challenges associated with quantification of low amounts of ammonia in the presence of a high concentration of sodium in sodium bicarbonate.
Application Note 1073: Determination of Ammonia in Sodium Bicarbonatedemonstrates that this assay meets the analytical performance characteristics recommended by United States Pharmacopeia (USP) General Chapter <1225>, including precisions (retention time relative standard deviation [RSD] less than 0.1% and peak area RSD less than 2%), accuracy (average recovery 88–117%), limits of detection, and robustness...