Members Login
Channels
Special Offers & Promotions
Electron Microscopy
Deben, a leading provider of in-situ testing stages together with innovative accessories and components for microscopy, reports on how amateur arachnologist Jeremy Poole uses the Deben Back-Scattered Electron Detector to image Britain’s spiders.
There are approximately 700 species of spider in Britain, these can be divided into 34 families and categorised further into separate genera. The main way to identify the species is by the spider’s sexual organs. Other factors that assist with identification are the number and layout of eyes, size of the chelicerae (jaws) and shape of the spinnerets. Jeremy likes to produce images from his Scanning Electron Microscope (SEM) that clearly illustrate these features, and is slowly building up a database of such images that is available on-line for anyone interested to consult (www.spiders.jeremypoolesem.org.uk).
In the process of imaging Jeremy regularly uses the Deben Generation 5 Back-Scattered Electron Detector (BSED) fitted to his FEI Inspect S50 SEM. This is called in to action regularly to help mitigate the effects of charging and also to soften the shadows that are such a feature of the conventional back-scattered electron detector. The detector is a 4 quadrant diode array positioned around a central hole which allows the electron beam to pass through. This design allows for consistent collection of electrons which are returned from the sample when it is scanned by the electron beam. The Deben detector is commonly used in the study of materials, but as is illustrated by Jeremy’s studies it can be useful in other applications too.
As a physicist and engineer by profession, rather than a biologist, Jeremy was always interested in the physics behind the SEM, and decided to add a BSED to his instrument to find out how this affected his images. The choice of Deben was made by his SEM maintenance engineer, but it was an easy decision. The alternative was to fit a detector supplied by the manufacturer of the SEM, but this would almost certainly have cost significantly more and the detector would probably have been made by Deben in any event. There were various configurations of BSED that could have been chosen. For example, the BSED could have been fitted inside the chamber and clipped on to the final aperture when it was required to use this mode of operation. However, after much deliberation it was decided to fit the Deben Generation 5 system, with an extending arm that moves the BSED into the correct position under software control, removing the need to return the pressure in the chamber to atmospheric to clip the detector in position and then vacuum down once more prior to using that detector.
The individual quadrants of the detector can be turned on or off, or even inverted in polarity, again under the control of the Deben software. This provides different insights into the subjects, or alternatively eye-catching images for their own sake. This is an area Jeremy has yet to explore seriously, although he has already had fun experimenting with various modes.
All of Jeremy’s specimens are captured in the wild, put to sleep using ethyl acetate and then preserved in Industrial Methylated Spirit. The subject is then dissected under a stereo microscope in a petri dish of alcohol and dried using a technique that prevents deformation of the tissues as they dry. Once the sample has successfully completed the drying process it is mounted onto a flat or angled aluminium stub (using double-sided adhesive carbon pads or carbon-based glue). They are placed into a vacuum chamber overnight to leach out any remaining solvents. The final step in preparing the specimens is to sputter-coat them with a thin layer of gold (~12nm). This step is carried out at low pressure in an argon atmosphere using the Quorum Technologies Q150R sputter coater.
Up to seven specimen stubs are loaded into the SEM for imaging at any one time. The orientation, magnification and focus are adjusted using the SEM computer interface. The brightness and contrast are also carefully adjusted to produce the best possible image. The Deben software helps Jeremy to select a good combination of brightness and contrast for his BSED images that can be fine-tweaked by hand using the same software. The final image is captured at a resolution of 2048x1887 and then goes through post-processing in Photoshop CC®.
Jeremy has been awarded the distinction of ‘Associate’ (ARPS) by The Royal Photographic Society (RPS) for his electron micrographs of spiders and a feature on his submission which was published in the October 2019 issue of the RPS Journal.
Referencs
The Spider Man – how Jeremy Poole ARPS turned a passion for arachnology in a Distinction. Royal Photographic Society. Journal Volume 159 Number 10, October 2019, Pages 716-720.
Learn more about Jeremy’s work
About Deben
Deben are a precision engineering company, established in 1986. They specialise in the field of in-situ tensile testing, motion control and specimen cooling for microscopy applications. The main product groups include: motor control systems, in-situ micro-tensile stages, Peltier heating & cooling stages, detectors for SEMs and electro-static beam blankers. Deben provide consultancy, design and prototype manufacturing services. In house facilities include SolidWorks and SolidEdge 3D CAD and COSMOS finite element analysis software, CNC machining, electronics design and manufacture and software design using Visual C++, Microsoft.net and DirectX. Deben UK Ltd. is a subsidiary company of UK based Judges Scientific plc.
Media Partners