In this latest video you will hear why people are choosing F-DSi Gas Generators over their other competitors.
End users talk about their experience of using FDGSi gas generators and share their feedback on the products and quality of service provided. Whatever are your needs, F-DSi gas generators enable you to produce Nitrogen, Hydrogen, Pure Air with purities higher than 99,9999%.
Genevac reports that its HT Series II Evaporator using the Fast Lyophilisation, or LyoSpeed™ process is enabling a growing number of pharmaceutical labs to routinely dry HPLC fraction samples to a powder form, such that the samples can then be accurately weighed, easily sub-sampled and redissolved.
When working with certain HPLC solvents, such as water and acetonitrile, a fully dried result can be hard to achieve due to interactions with the dissolved sample - resulting in the formation of a gum or oil. To provide a rapid, high-throughput alternative to freeze drying HPLC purification fractions - Genevac developed its proprietary fast lyophilisation (LyoSpeed™) methodology for use on the HT Series II Evaporators. While LyoSpeed™ works well for most hydrophilic samples, difficulties may arise where the sample cannot dissolve in only water...
The launch of the Viscotek SEC-MALS 20 brings new standards of performance and greater choice in gel permeation/size exclusion chromatography (GPC/SEC) and extends the Malvern Instruments family of light scattering detectors for measuring the absolute molecular weight of proteins, macromolecules and polymers.
Malvern’s Viscotek range now includes cost-effective options with unsurpassed performance for every type of light scattering detection – low angle, right angle and multi angle – allowing Malvern to answer every GPC/SEC challenge with the most appropriate technology. With this extension to its detectors range, Malvern becomes the only vendor to offer all light scattering options....
With the Flexar™ PDA Plus™, the latest addition to the PerkinElmer Flexar liquid chromatography product family, scientists analyzing environmental, food, pharmaceutical and chemical samples can now better meet industry regulations and higher throughput demand.
This innovative technology brings the flexibility of modular design, the power of sensitivity and accuracy and the fastest sampling speeds to the most optically advanced photo diode array (PDA) detector on the market. Its design encompasses the widest detection range of any PDA detector on the market and rivals or exceeds that of conventional UV detectors. Delivering improved 2D and 3D chromatographic information, the PDA detector streamlines analysis with the following features...
New MEDICA Pro EDI Water Purification System for clinical diagnostic laboratories
PULSE EDI technology and unique recirculation for economical and consistent high purity water. ELGA Process Water, a Veolia Water Solutions & Technologies company, introduces the MEDICA Pro EDI - a new EDI (Electrodeionisation) water purification system for clinical diagnostic market. The MEDICA Pro EDI has been developed to produce consistently high purity water at economical running costs for a wide range of applications in modern clinical laboratory including immunochemistry and general chemistry automatic clinical analysers...
The new Chromatography Columns and Supplies Catalogue 9 from Hichrom Limited has arrived. With 384 pages of detailed chromatography product information and other useful technical data, this catalogue is an essential tool for every laboratory.
Contained within the catalogue is information on over 100 LC column brands and details of products from over 35 chromatography suppliers. In addition to HPLC, UHPLC and superficially porous particle columns, the new catalogue contains details of SFC, GC, SPE, TLC, Flash, CE, LC-MS and GC-MS products. Vials, syringe filters, tubing, fittings and other chromatography accessories are also included.....
Thermo Fisher Scientific has developed an accurate and reproducible high-performance liquid chromatography (HPLC) method for the single-injection determination of tolterodine and tartrate—the active pharmaceutical ingredient (API) and its counterion—in an encapsulated drug product containing tolterodine tartrate.
Application Note 1047: Simultaneous Determination of Tartaric Acid and Tolterodine in Tolterodine Tartrate demonstrates that this method requires only 13 minutes per analysis. This new approach uses a trimode silica-based column and a detector that is ideal for the determination of counterions, many of which lack a chromophore. Pharmaceutical companies must ensure that a drug product contains the appropriate amount of its API. This is typically validated with an HPLC-based assay...
Thermo Fisher Scientific, Inc., the world leader in serving science, recently launched the Thermo Scientific SureStop 9 mm Vial.
It is designed as part of the Advanced Vial Closure System (AVCS), and removes any subjectivity around achieving the optimal compression of the septum when sealing a chromatography vial. As an integral component of AVCS technology, SureStop 9 mm vials offer the sealing and performance characteristics of a crimp top vial with the versatility and convenience of a threaded vial...
Thermo Fisher Scientific has developed a new GC-MS method for the analysis of semi-volatile organic compounds (SVOCs) in accordance with U S. EPA Method 8270 using hydrogen carrier gas.
Key modifications to both GC and MS hardware and methods are necessary for successfully switching to hydrogen. Fast GC-MS Analysis of Semi-Volatile Organic Compounds: Migrating from Helium to Hydrogen as a Carrier Gas in US EPA Method 8270, featuresthe Thermo Scientific™ TRACE™ 1310 GC coupled to a Thermo Scientific™ ISQ™ single quadrupole mass spectrometer using hydrogen as a carrier gas. The final, optimized EPA Method 8270 is fully migrated to hydrogen carrier gas with improved peak shape, resolution, and run time...
Kinesis has launched its own range of syringe filters.
Available in a wide choice of membranes and diameters, KX Syringe Filters reliably and reproducibly filter all sample types from small volume biological fluids to large volume environmental samples. Choose from the following membranes, Glass Fibre, Nylon, PES, Polypropylene, PTFE, Hydrophilic PTFE, PVDF, Mixed Cellulose Esters and Regenerated Cellulose for all aqueous and non-aqueous samples...
The New AxION iQT GC/MS/MS System Combines the Quantitative Power of a Triple Quad with the Identification Capabilities of a Q-TOF in a Faster, Modular and Easier to Operate Instrument
At the 2013 American Society for Mass Spectrometry Conference, PerkinElmer Inc., a global leader focused on the health and safety of people and the environment, introduced the AxION iQT gas chromatography tandem mass spectrometer (GC/MS/MS). The AxION iQT system provides greater quantitative capabilities to that of a triple quadrupole, while quickly identifying compounds like a quadrupole time-of-flight (Q-TOF) at a rate of up to 500 compounds per second. The new mass spectrometer provides laboratories with easier to use technology, faster results, and more specific, selective data needed to make more accurate decisions faster.....
Malvern Instruments has published ‘Static Light Scattering Technologies For GPC/SEC Explained’, a valuable guide for anyone assessing the value of a light scattering detector for gel permeation/size exclusion chromatography (GPC/SEC).
Covering the theory and practice of molecular weight measurements using static light scattering, this basic guide serves as both an introduction for those with no prior knowledge of the technique and a reference document for anyone looking to enhance their understanding. The white paper is available as a free download from the Malvern Instruments website
Read MoreExtraction of Metaldehyde, Geosmin and 2-Methylisoborneol from WaterJul 16, 2013
Kinesis has published a new Application Note: Extraction of Metaldehyde, Geosmin and 2-Methylisoborneol from Water
The latest TELOS® SPE Application Note from Kinesis highlights the extraction of Metaldehyde, Geosmin and 2-Methylisoborneol from Water. Metaldehyde is a molluscicide whose use has markedly increased in recent years as a result of changing agricultural practices. Geosmin and 2-methylisoborneol (MIB) are naturally occurring alicyclic alcohols which possess potent earthy/musty taste and odour tainting properties. They can occur in raw and potable waters as metabolites derived from various micro-organisms...
A series of technical papers are available from Genevac that demonstrate the advantages and benefits that their proprietary SampleGenie technology offers to chemical, environmental and food labs tasked with pooling and concentrating GC and HPLC fractions.
Traditional protocols for concentration of GC or HPLC fractions has involved drying multiple fractions in an evaporator, re-suspending pooled fractions into a single vial and then re-drying before storage and analysis. Even with modern centrifugal evaporators such processes typically take 2-3 days to complete. The development of SampleGenie™ technology enables samples in Genevac evaporators to be concentrated, without loss of volatile components, directly into a single GC or HPLC vial eliminating the need for reformatting of samples after drying...
Thermo Fisher Scientific has developed an ion chromatography method for nuclear power plants (NPPs) that determines trace concentrations (less than 1 µg/L) of fluoride, chloride, and sulfate in simulated secondary feed water that contains ethanolamine, hydrazine, and polyacrylic acid in just 20 minutes.
Application Brief (AB) 151: Determination of Trace Anions in Nuclear Power Plant Secondary Feed Water Containing Polyacrylic Acid demonstrates excellent retention time and peak area reproducibilities from 69 consecutive injections of a spiked simulated sample...
Organomation presents one of their most advanced accessories to date, a newly revamped Nitrogen Generator. This compact unit will provide laboratory technicians with their own source of nitrogen for reduced cost and increased productivity.
Sales and Marketing Manager David Oliva stated that "one of the main concerns related to using blow down evaporators is the cost of nitrogen consumption over time. Our newly designed nitrogen generator will help users avoid the costs associated with purchasing and replacing nitrogen tanks."...
Thermo Fisher Scientific has developed an efficient high-performance liquid chromatography (HPLC) method using ultraviolet detection for the simultaneous determination in drinking water of all 19 phthalate compounds listed in key environmental regulatory documents.
Application Note 1045: Determination of Phthalates in Drinking Water by UHPLC with UV Detection demonstrates that the phthalates listed in European Union Directive 2005/84/EC, U.S. Environmental Protection Agency Methods 606 and 8061A, the Chinese HJ/T 72-2001, and the Standardization Administration of China GB/T 20388-2006 and GB/T 21911-2008 are well separated on a reversed-phase HPLC column in less than 25 minutes...
Thermo Fisher Scientific has released additions of WAX and WCX phases for bioanalysis to its revolutionary SOLA solid-phase extraction (SPE) product line. The new phases are available in cartridge and plate formats.
Thermo Scientific SOLA products are the first fritless SPE cartridges and plates, offering: unsurpassed reproducibility at low elution volumes, low failure rates, enhanced sensitivity, and clean sample extracts. The novel design eliminates voiding, channeling and packing inconsistencies that can cause analytical failures or poor reproducibility. Thermo Scientific SOLA products revolutionize Solid Phase Extraction (SPE). This first fritless SPE product range provides greater reproducibility with cleaner, more consistent extracts. SOLA products provide unparalleled performance characteristics compared to conventional SPE, phospholipid removal and protein precipitation products...
Thermo Fisher Scientific Inc. introduces a new HPLC column, the Thermo Scientific MAbPac Protein A column, for high-performance monoclonal antibody titer analysis.
This HPLC column is specially designed for higher sensitivity and accurate concentration analysis over a wide linear range to minimize the need to re-analyze samples. Its novel non-porous polymeric resin with hydrophilic surface offers fast mass transfer to enhance throughput and minimize carryover. Low backpressure design accommodates high flow rates to further increase throughput. Concentrated peaks are suitable for additional chromatography or other analyses...
In a new paper published in Polymers & Polymer Composites (Vol 21, No 1, 2013), researchers at Kingston University in the UK report the results of continuing work to examine the effects of gamma irradiation on intraocular lenses (IOLs) used in cataract surgery. Triple detection gel permeation chromatography (GPC) using the Viscotek TDAmax system from Malvern Instruments was a key analytical tool in this work.
Baljit Ghatora and co-authors examined medical grade poly(methyl methacrylate) (PMMA), which is used especially widely in developing countries to make rigid intraocular lenses and for which low cost, convenient gamma irradiation is increasingly the preferred method for sterilisation. Previous reports have suggested that gamma irradiation has the potential to alter the structural features of the polymer, such as molecular weight and molecular size distribution, which in turn may impact the efficacy and performance of IOLs....
Read MoreNew High Recovery Vial Convenience KitsJun 26, 2013
You can now choose from our standard 12x 32 high recovery vial in a series of Convenience Kits or allow us to design and engineer a vial for your specific requirements and automation systems.
NEW High Recovery Convenience Kits include:
12x32 mm clear vial, 11mm crimp finish, tapered bottom
With 11mm Aluminum Seal with PTFE/Red Rubber
With 11mm Aluminum Seal with PTFE/Silicone
With 11mm Aluminum Seal with PTFE/Silicone/PTFE.....
An improvement on existing 96-Well systems, the Multi-Tier Plate is a modular, reusable system featuring a base plate capable of securing 0.5, 1.0, 1.5, or 2.0 mL conical glass, flat bottom and polypropylene vials.
The vented design of the base plate assures uniform heating and cooling when immersed in a water bath. The cover locks the liner in place and prevents vial pullout. The prescored PTFE/Silicone/PTFE liner permits easy needle penetration, while the Molded PTFE/Silicone liner locks into each of the 96 vials and reseals after multiple injections thus reducing the chance of solvent evaporation and cross contamination....