Channels

 

Special Offers & Promotions

 

 

Latest News

 

 

View Channel

New Products

 

 

View Channel

Video Presentations

 

 

View Channel

Separation Science

 

 

View Channel

Microscopy & Image Analysis

 

 

View Channel

Laboratory Automation & IT Solutions

 

 

View Channel

 

Thermo Fisher Scientific Introduces MetQuest Automated Metabolic Screening Software Allowing a Quantitative/Qualitative Workflow to Revolutionize Drug Metabolism and Pharmacokinetic Studies at ASMS 2010

Thermo Scientific MetQuest.jpgSALT LAKE CITY, Utah (May 24, 2010) - Thermo Fisher Scientific Inc., the world leader in serving science, today introduced Thermo Scientific MetQuest, its software solution that enables laboratories to take full advantage of powerful Thermo Scientific Orbitrap mass spectrometry (MS) high-resolution accurate-mass (HRAM) full-scan data to perform quantitative metabolic stability studies and identify putative metabolites in a single injection. MetQuestTM software is designed to provide researchers performing drug metabolism and pharmacokinetic (DMPK) studies a significant time and cost savings when compared to traditional multiple reaction monitoring (MRM) methods. MetQuest software will be demonstrated at the Salt Palace Convention Center Salons 250BCEF, May 24 - May 26, 2010 during the  ASMS Conference on Mass Spectrometry and Allied Topics in Salt Lake City, Utah. 

In combination with the industry-proven Thermo Scientific LTQ Orbitrap or Exactive families of liquid chromatography/mass spectrometry (LC/MS) systems, MetQuest software enables researchers to routinely perform quantitative and qualitative analyses in the same run. This solution is designed to offer substantial time and cost savings compared to triple quadrupole MRM approaches for metabolic studies. Publications from Zhang et al and Bateman et al report that quantitative results, including precision, accuracy, linearity and sensitivity for parent drugs and their metabolites, are comparable to those for established triple quadrupole MRM methods.    

"Obtaining both quantitative and qualitative information more effectively and earlier in the discovery process is paramount for the pharmaceutical industry," said Patrick Bennett, director of marketing for scientific instruments at Thermo Fisher Scientific. "MetQuest software allows users to quantify and identify compounds and their metabolites simultaneously, and interrogate data later for additional information without having to re-run the entire experiment, which typically includes sample preparation and LC/MS analysis. This turn-key solution offers significant benefits to the industry and will revolutionize the way LC/MS experiments are performed in DMPK labs."  

Understanding and documenting the metabolism of drug candidates is a key step in early-stage drug discovery. Traditionally, triple quadrupole systems using MRM methods have been used for compound quantitation. While the specificity of MRM is a key strength of these systems, it is also a limitation. MRM methods are effective in detecting a particular compound, but information about other components present in the sample, e.g. metabolites, may not be captured unless an MRM method is pre-defined to detect them.  It also requires time-consuming selection and optimization of MRM parameters, such as precursor ions, product ions, declustering and collision energies, for each target analyte of interest. The time, effort and skill level required is significant for laboratories that must analyze many new chemical entities every day.  

The patented Orbitrap technology is ideal for compound identification and high-throughput screening for simultaneous qualitative and quantitative analyses. Its ultra-high mass resolution up to 100,000 filters out chemical noise such as isobaric interferences from biological matrices, enabling low detection limits and fewer false positives. The patents-pending processing methods in MetQuest software have been specifically developed to automatically process full-scan high resolution data for compound identification from even the most complex biological matrices without the need for pre-defined mass-to-charge values.  Because MetQuest software does not require time-consuming MS/MS method development and optimization, acquisition methods are more simple to set up and a single method can be used for multiple compounds. The automated generation of metabolic stability plots from the processed data saves time compared to manual generation of plots using other software. 

For more information about MetQuest Software, or other Thermo Scientific products, please visit Thermo Scientific booth 69 or the Thermo Scientific hospitality suite at the Salt Palace Convention Center Salons 250BCEF during ASMS 2010. For more information about Thermo Scientific mass spectrometry solutions, please call 1-800-532-4742, or visit www.thermoscientific.com


If you have not logged into the website then please enter your details below.



 

News Channels

 

 

Subscribe to any of our newsletters for the latest on new laboratory products, industry news, case studies and much more!

Newsletters from Lab Bulletin

 

Request your free copies HERE

 

 

 

Popular this Month

Top 10 most popular articles this month

 

 

Today's Picks

 

 

 

 

Looking for a Supplier?

Search by company or by product

 


Company Name:

Product:


 

 

 

 

Please note Lab Bulletin does not sell, supply any of the products featured on this website. If you have an enquiry, please use the contact form below the article or company profile and we will send your request to the supplier so that they can contact you directly.

Lab Bulletin is published by newleaf marketing communications ltd.


 

Media Partners

 

Exhibitions & Events