Channels

 

Special Offers & Promotions

 

 

Latest News

 

 

View Channel

New Products

 

 

View Channel

Video Presentations

 

 

View Channel

Separation Science

 

 

View Channel

Microscopy & Image Analysis

 

 

View Channel

Laboratory Automation & IT Solutions

 

 

View Channel

 

3 Steps to Safer and Simpler DNA Gel Electrophoresis.

Helping to make DNA electrophoresis procedures safer, more convenient and more economical are the fundamental principles behind the development of the ‘Safe’ Series of products from CLEAVER SCIENTIFIC (CSL).

DNA gel Electrophoresis AB13-610Laboratories around the world will acknowledge that there are two main hazards with traditional DNA gel electrophoresis.  For example, the stain most commonly used is Ethidium Bromide which is a mutagen and carcinogen, whilst the illumination source most often used is Ultra Violet, which can cause eye and skin damage.  Furthermore, traditional DNA electrophoresis is usually performed without the researcher knowing much about what is happening on the gel unit until is stopped and checked.

This is essentially a ‘blind, stop and start’ process where the electrophoresis run is stopped at the time the researcher thinks that the samples have separated out enough.

The gel is then taken to another room for checking and photographing and if the samples have not run enough, the gel is taken back to the tank and the time consuming process is repeated. If the samples have run too far the situation is worse because an entire new gel must be cast and run.

The ‘Safe’ Series offers a safer and more user-friendly alternative to traditional methods as it eliminates the need for Ethidium Bromide and the need for ultra violet light, without compromising the results of electrophoresis procedures.

The ‘Safe’ Series comprises runSafe, a completely safe stain for DNA and runView, a gel electrophoresis system that utilises safe blue light and finally runDoc, a bench top gel documentation system which sits above the gel tank and enables multiple real-time images of the process to be taken.

With runView and runSafe, the separation of the DNA bands can be viewed in real-time, allowing the researcher to have complete control of the time of the electrophoresis run to achieve exactly the separation required.

In summary, the runView, runSafe and runDoc system provides a safe, economic, convenient and easy-to-use integrated solution for DNA electrophoresis covering each stage of the process.  It enables casting, loading, running, staining, viewing and documentation of DNA and RNA gels in a completely safe environment which requires no additional equipment, space or dark room.


more about  DNA gel electrophoresis


more about Cleaver Scientific


more news from Cleaver Scientific


 


If you have not logged into the website then please enter your details below.



 

News Channels

 

 

Subscribe to any of our newsletters for the latest on new laboratory products, industry news, case studies and much more!

Newsletters from Lab Bulletin

 

Request your free copies HERE

 

 

 

Popular this Month

Top 10 most popular articles this month

 

 

Today's Picks

 

 

 

 

Looking for a Supplier?

Search by company or by product

 


Company Name:

Product:


 

 

 

 

Please note Lab Bulletin does not sell, supply any of the products featured on this website. If you have an enquiry, please use the contact form below the article or company profile and we will send your request to the supplier so that they can contact you directly.

Lab Bulletin is published by newleaf marketing communications ltd.


 

Media Partners

 

Exhibitions & Events