Accurate & Precise Micro Determination of Fluorine
Operating
in an ISO 17025 and GMP accredited environment, Warwick Analytical Service has
developed proprietary analytical procedures to enable accurate and precise data
to be produced for all types of samples including organic samples with trace
levels of Fluorine.
From extensive method validation typical results are within the ±0.3% absolute limits considered acceptable for micro chemical analysis. The WAS method can detect 0.01ppm fluoride which is equivalent to 0.02% in a 10mg sample. WAS has developed special procedures to remove interferences from samples containing boron, calcium or sulfur.
Offered by Warwick Analytical Service (WAS) as an analytical service, analysis of Fluorine is carried out by combustion of an accurately weighed sample in a silica oxygen flask over an accurately measured volume of water and TISAB buffer solution. A fluoride ion selective electrode is used to directly measure the potential of a range of fluoride solutions. The potential of the combusted samples are measured under the same conditions. The concentrations of the sample solutions are calculated from the derived calibration curve. Sets of work typically include certified reference materials or organic analytical standards. Results from these standards and the electrode response are monitored to detect trends in the method.
The accurate micro determination of fluorine in organic compounds is of significant interest to a wide array of industries including food and beverages, environmental monitoring, medical, pharmaceutical and polymers.
Warwick Analytical Service (WAS) is a company dedicated to providing analytical excellence at a realistic cost. Through experienced staff, the latest analytical instrumentation and working closely with clients - WAS has established a strong reputation for informed personal service and delivering top quality data on time. Operating from a dedicated facility approved to BSI ISO 9001 and with a wide range of analytical techniques accredited to UKAS ISO17025 - WAS has become the trusted analytical services provider for a growing number of UK and international businesses. From its modern, well-equipped facility in Coventry, UK - Warwick Analytical Services offers a wide range of analytical techniques including elemental analysis (ICP, CHNS, Halogen analysis), Optical Rotation, NMR, MS, FT-IR, Thermal Analysis and Particle sizing on a contract basis.
For full details of micro determination of fluorine in organic compounds please contact Warwick Analytical Service on tel. +44-2476-323223 or email info@warwickanalytical.co.uk
From extensive method validation typical results are within the ±0.3% absolute limits considered acceptable for micro chemical analysis. The WAS method can detect 0.01ppm fluoride which is equivalent to 0.02% in a 10mg sample. WAS has developed special procedures to remove interferences from samples containing boron, calcium or sulfur.
Offered by Warwick Analytical Service (WAS) as an analytical service, analysis of Fluorine is carried out by combustion of an accurately weighed sample in a silica oxygen flask over an accurately measured volume of water and TISAB buffer solution. A fluoride ion selective electrode is used to directly measure the potential of a range of fluoride solutions. The potential of the combusted samples are measured under the same conditions. The concentrations of the sample solutions are calculated from the derived calibration curve. Sets of work typically include certified reference materials or organic analytical standards. Results from these standards and the electrode response are monitored to detect trends in the method.
The accurate micro determination of fluorine in organic compounds is of significant interest to a wide array of industries including food and beverages, environmental monitoring, medical, pharmaceutical and polymers.
Warwick Analytical Service (WAS) is a company dedicated to providing analytical excellence at a realistic cost. Through experienced staff, the latest analytical instrumentation and working closely with clients - WAS has established a strong reputation for informed personal service and delivering top quality data on time. Operating from a dedicated facility approved to BSI ISO 9001 and with a wide range of analytical techniques accredited to UKAS ISO17025 - WAS has become the trusted analytical services provider for a growing number of UK and international businesses. From its modern, well-equipped facility in Coventry, UK - Warwick Analytical Services offers a wide range of analytical techniques including elemental analysis (ICP, CHNS, Halogen analysis), Optical Rotation, NMR, MS, FT-IR, Thermal Analysis and Particle sizing on a contract basis.
For full details of micro determination of fluorine in organic compounds please contact Warwick Analytical Service on tel. +44-2476-323223 or email info@warwickanalytical.co.uk