Waters BioResolve RP mAb Polyphenyl Columns, Setting a New Standard for Reversed-Phase Separations of Monoclonal Antibodies and Antibody Drug Conjugates

publication date: Feb 13, 2018
 | 
author/source: Waters Corporation

Waters' new BioResolve RP mAb Polyphenyl Columns are for the analysis of intact or sub-unit-digested monoclonal antibodies (mAbs) and antibody-drug conjugates (ADCs) by reversed phase liquid chromatography (LC) and LC-mass spectrometry

Waters Corporation (NYSE:WAT) has introduced BioResolve™ RP mAb Polyphenyl 450 angstrom 2.7 micron solid core Columns intended for the reversed-phase analysis of intact or sub-unit-digested monoclonal antibodies (mAbs) and antibody-drug conjugates (ADCs) using LC-UV and LC-MS.

In addition to getting performance-driven columns, users of BioResolve brand columns will receive application-focused standards, templated methods, and an enhanced level of applications support to help ensure that they can consistently and reliably perform state-of-the-art bioseparations.

“A segment of the scientist community regards mAb and ADC separations as overly complex. The causes of their frustrations are many and they include poor data quality, degradation of the target mAbs, poor recovery, excessive carryover and erratic results due to column-to-column irreproducibility. To address these issues, we tasked our research scientists to engineer a column that would raise the bar for separation performance and take the hassle out of the measurement process,” said Dr. Erin Chambers, Vice President, Chemistry, Waters Corporation. ”Our ultimate goal is to enable biopharmaceutical scientists to generate consistent results that meet international regulatory requirements to confirm product efficacy and safety.”

Jacquelynn Smith, a member of Pfizer’s Analytical Research and Development Department, St. Louis, Missouri who has evaluated the BioResolve RP mAb Polyphenyl Column, said, “The newly introduced BioResolve RP mAb Polyphenyl wider pore column provides superior recovery, separation and resolution of therapeutic monoclonal antibody (mAb) subunits and domains, as compared to other RP C4 columns on the market. This resulted in higher quality product profiles for mAbs and antibody drug conjugates, especially when hydrophobic subunits and domains were encountered. The BioResolve RP mAb Polyphenyl column addresses the key challenges of mAb and ADC subunit/domain analysis, helps toward right-first time analyses, and will be a valuable addition to our characterization toolbox.”

Her poster, High Resolution Chromatography – Mass Spectrometry with a Novel Phenyl RPLC Column for Heightened Characterization of Hydrophobic Monoclonal Antibodies and Antibody Drug Conjugates, was presented at the 22nd Symposium on the Interface of Regulatory and Analytical Sciences for Biotechnology Health Products (WCBP) in Washington, D.C.

With the introduction of BioResolve RP mAb Polyphenyl Columns, Waters continues its commitment to the biopharmaceutical industry by meeting the needs of analytical scientists and lab managers across the discovery, development and manufacturing pipeline.

Performance-Driven Particle and Bonding Technology

The combination of the BioResolve RP mAb Polyphenyl Column 450 angstrom solid-core particle design and proprietary polyphenyl ligand bonding makes it especially well-suited for reversed phase separations of intact mAbs, IdeS generated fragments and similarly sized proteins. These columns establish a new industry standard for separation selectivity, efficiency, sample recovery and low injection-to-injection carryover even when operated at lower temperatures.

The BioResolve RP mAb Polyphenyl 450 angstrom 2.7 micron Columns are available in lengths of 50, 100 or 150 millimeters and internal diameters of 2.1 or 4.6 millimeters for compatibility with UltraPerformance Liquid Chromatography ™ (UPLC), Ultra-High Performance Liquid Chromatography (UHPLC) or High Performance Liquid Chromatography (HPLC) separations platforms thus facilitating easy method transfer between discovery, development and manufacturing/QC applications.

In addition, the columns are shipped with the same reduced IdeS-digested NIST reference material that Waters uses to quality-test each batch of stationary phase.

The new BioResolve RP mAb Polyphenyl Columns are now available worldwide from Waters.

Find out more


About Monoclonal Antibodies and Antibody Drug Conjugates

Monoclonal antibodies (mAbs) are the largest and fastest-growing segment of the biotherapeutics market. They are a distinct type of bioengineered molecule designed to sequester target proteins and/or modify cellular pathways linked to a disease state. Like natural antibodies, they are potent and highly selective for the targets they engage whether the targets are outside cells or on the cells themselves. They can also stimulate the immune system and mount a broader immune defense against a disease like cancer. In one of the better known examples of their therapeutic potential, former U.S. President Jimmy Carter’s stage-four melanoma was sent into remission with Merck’s mAb, Keytruda.

Antibody drug conjugates (ADCs) are highly-potent, monoclonal antibodies engineered to deliver a cytotoxic (anticancer) payload or drug to tumor cells while sparing healthy cells. Their physico-chemical characterization requires a large number of assays aimed at verifying their molecular weight, sequence identity and post-translational modifications.

The path to the commercialization of these and future drugs is paved with information derived from LC and LC-MS analyses which are essential for identifying critical quality attributes at all stages of the discovery, development and manufacturing of mAbs.


About Waters Corporation

Waters Corporation (NYSE: WAT), the world's leading specialty measurement company, has pioneered chromatography, mass spectrometry, and thermal analysis innovations serving the life, materials, and food sciences for nearly 60 years. With approximately 7,000 employees worldwide, Waters operates directly in 31 countries, including 15 manufacturing facilities, and with products available in more than 100 countries.

Waters, UPLC and BioResolve are trademarks of Waters Corporation.


If you have not logged into the website then please enter your details below.



 

Subscribe to any of our newsletters for the latest on new laboratory products, industry news, case studies and much more!

Newsletters from Lab Bulletin

 

Request your free copies HERE

 

 

 

Popular this Month

Top 10 most popular articles this month

 

 

Today's Picks

 


 

Looking for a Supplier?

Search by company or by product

 


Company Name:

Product:


 

 

 

 

Please note Lab Bulletin does not sell, supply any of the products featured on this website. If you have an enquiry, please use the contact form below the article or company profile and we will send your request to the supplier so that they can contact you directly.

Lab Bulletin is published by newleaf marketing communications ltd.


 

Media Partners

 

Exhibitions & Events